High rejection BWRO, enhanced chemical tolerance
T M 7 0 0D
12,100(45.8)
11,000(41.6)
11,000(41.6)
2,600(9.8)
28
34
31
31
99.8440(41)8”TM720D-440
99.8400(37)8”TM720D-400
99.8400(37)8”TM720DA400
99.887(8)4”TM710D
2,150gpd(8.2m3
/d)(TM710D)
8,900gpd(33.6m3
/d)(TM720DA400)
8,900gpd(33.6m3
/d)(TM720D-400)
9,800gpd(37.0m3
/d)(TM720D-440)
4. Minimum Product Flow Rate
3. Minimum Salt Rejection 99.65%
225 psi(1.55MPa)
77°F(25℃)
2,000 mg/l Nacl
15%
7
Feed Water Pressure
Feed Water Temperature
Feed Water Concentration
Recovery Rate
Feed Water pH
2. Test Conditions
1. Membrane Type Cross Linked Fully Aromatic Polyamide Composite
Dimensions
All dimensions shown in Inches (millimeter).
1.05(26)
0.75(19)
4(101)
TM710D
Feed Water
Concentrated Brine
F
B
40(1,016)
40(1,016)
Flow direction
PERMEATE
B
B
F
F
Flow direction
PERMEATE
B
B
F
F 1.125(29)
7.9(201
TM720DA400 )
TM720D-400
TM720D-440
Product Flow Rate
gpd(m3
/ d)
Feed Spacer
Thickness
mil
Salt Rejection
%
Membrane Area
ft2
(m2
)
Diameter
Inch
Type
Operating Limits
1. For the recommended design range, please consult the latest Toray technical bulletin, design guide
lines, computer design program, and/ or call an application specialist. If the operating limits given in this
Product Information Bulletin are not strictly followed, the Limited Warranty will be null and void.
2. All elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and
then vacuum packed in oxygen barrier bags, or treated with tested feed water solution, and then
vacuum packed in oxygen barrier bags with deoxidant inside. To prevent biological growth during short
term storage, shipment, or system shutdown, it is recommended that Toray elements be immersed in a
protective solution containing 500 – 1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.
3. The presence of free chlorine and other oxidizing agents under certain conditions, such as heavy
metals which acts as oxidation catalyst in the feed water will cause unexpected oxidation of the
membrane. It is strongly recommended to remove these oxidizing agents contained in feed water
before operating RO system.
4. Permeate from the first hour of operation shall be discarded.
5. The customer is fully responsible for the effects of chemicals that are incompatible with the elements.
Their use will void the element Limited Warranty.
1. Toray accepts no responsibility for results obtained by the application of this information or the safety or
suitability of Toray’s products, either alone or in combination with other products. Users are advised to
make their own tests to determine the safety and suitability of each product combination for their own
purposes.
2. All data may change without prior notice, due to technical modifications or production changes.
JUL. 2013
Maximum Operating Pressure
Maximum Feed Water Temperature
Maximum Feed Water SDI15
Feed Water Chlorine Concentration
Feed Water pH Range, Continuous Operation
Feed Water pH Range, Chemical Cleaning
Maximum Pressure Drop per Element
Maximum Pressure Drop per Vessel
600psi (4.1 MPa)
113°F (45℃)
5
<0.1ppm
2-11
1-13
20psi (0.14 MPa)
60psi (0.4 MPa)
Operating Information
Notice
Asia and Oceania:
Toray Industries, Inc.
RO Membrane Products Department
1-1, Nihonbashi muromachi 2-chome
Chuo-ku, Tokyo 103-8666, Japan
Tel : +81 3 3245 4540
Fax: +81 3 3245 4913
http:/ / www.toraywater.com
Americas:
Toray Membrane USA, Inc.
Sales Office
13435 Danielson St,
Poway, CA 92064, USA
Tel: +1 858 218 2390
Fax: +1 858 486 3063
Europe, Middle East and Africa:
Toray Membrane Europe AG
Grabenackerstrasse 8
CH-4142 Münchenstein 1, Switzerland
Tel: +41 61 415 87 10
Fax: +41 61 415 87 20
CHINA:
Toray BlueStar Membrane Co., Ltd.
No.5 Anxiang Street, Area B,
Beijing Tianzhu Airport Economic Development Zone,
Beijing ,101318 P.R.C.
Tel: +86 10 80490552
Fax: +86 10 8048521